VOKERA Linea Service Manual Page 18

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 17
16
Linea
Fig. 16
Connect the supply cable wires (LIVE, and NEU-
TRAL) to their corresponding terminals on the
appliance terminal block. Connect the EARTH
wire to the EARTH block (see fig. 16) ensuring
that it’s left slightly longer that the others, this will
prevent strain on the EARTH wire should the
cable become taut.
Do not remove the link wire (between TA & Spare)
unless additional external controls are to be fit-
ted (see section 8).
4.7.4 CONNECTING THE VOKERA TIME CLOCK
(part no. 201 & 202)
The appliance is supplied with a clock connector
plug that is connected to plug M16 on the appli-
ance terminal block. The clock connector plug is
for use with the clock harness that is included in
the accessory pack and facilitates an easy con-
nection to the optional Vokera time clock.
To fit the Vokera time clock:
Remove the appliance PCB cover.
Remove and discard the wiring harness sup-
plied with the clock.
Using the clock wiring harness supplied in the
accessory pack, connect the 4-wires to the
clock as shown in fig 16.
Remove the clock aperture plate from the ap-
pliance.
Remove the push-out blanking disc from the
clock aperture plate (fig. 17).
Secure the clock to the aperture plate using the
screws provided with the clock (fig. 17).
Refit the clock aperture plate ensuring the clock
is positioned the correct way up.
Remove the Red link-wire plug from the appli-
ance clock connector plug.
Connect the clock wiring harness to the clock
connector plug.
Re-fit the appliance PCB cover and terminal
cover.
The securing screw on the cable anchorage
should now be tightened. This must be done be-
fore the control fascia is re-fitted in the upright
position. The appliance casing and screws can
now be re-fitted.
Fig. 17