3.10 TIMBER FRAMED BUILDINGS
If the appliance is to be fitted in a timber framed
building, it should be fitted in accordance with the
Institute of Gas Engineers publication (IGE/UP/
7) ‘Guide for Gas Installations in Timber Frame
Buildings’.
3.11 INHIBITORS
Vokera recommend that a inhibitor – suitable for
use with low water-content, copper heat exchang-
ers – is used to protect the boiler and system
from the effects of corrosion and/or electrolytic
action. The inhibitor must be administered in strict
accordance with the manufacturers* instructions.
*Fernox and Sentinel manufacture products that
have proved suitable for use with Vokera appli-
ances. Vokera Ltd. cannot comment on the suit-
ability of any other such product with our appli-
ances.
Fig. 6
This appliance must be installed by a competent
person in accordance with and defined by, the
Standard Specification (Domestic Gas Installa-
tions) Declaration (I.S. 813).
3A.1 RELATED DOCUMENTS
The installation of this boiler must be in accord-
ance with the relevant requirements of the local
building regulations, the current ETCI National
Rules for Electrical Installations, and the bylaws
of the local water undertaking.
It should be in accordance also with any relevant
requirements of the local and/or district authority.
3A.2 LOCATION OF APPLIANCE
The appliance may be installed in any room or
internal space, although particular attention is
drawn to the requirements of the current ETCI
National Rules for Electrical Installations, and I.S.
813, Annex K.
When an appliance is installed in a room or in-
ternal space containing a bath or shower, the ap-
pliance or any control pertaining to it must not be
SECTION 3A GENERAL REQUIREMENTS (EIRE)
within reach of a person using the bath or shower.
The location chosen for the appliance must per-
mit the provision of a safe and satisfactory flue
and termination. The location must also permit
an adequate air supply for combustion purposes
and an adequate space for servicing and air cir-
culation around the appliance. Where the instal-
lation of the appliance will be in an unusual loca-
tion special procedures may be necessary, refer
to I.S. 813 for detailed guidance on this aspect.
A compartment used to enclose the appliance
must be designed and constructed specifically for
this purpose. An existing compartment/cupboard
may be utilised provided that it is modified to suit.
This appliance is not suitable for external instal-
lation.
3A.3 GAS SUPPLY
The gas meter – as supplied by the gas supplier
– must be checked to ensure that it is of adequate
size to deal with the maximum rated input of all
the appliances that it serves. Installation pipes
must be fitted in accordance with I.S. 813.