VOKERA Linea Service Manual Page 36

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 35
34
Linea
DOES
BURNER
LIGHT
CHECK BOILER
STARTUP:
TEST A
TURN ON TAP
TURN MODE
SELECTOR SWITCH TO
DHW.
DHW STAT AT MAX.
START
TEST B : CHECK CONTROL
IN DHW MODE
TURN DHW
THERMOSTAT AT
MIN.
DO
BURNER AND FAN
SWITCH OFF
IS
WATER FLOW
TEMPERATURE
>40 ûC
WAIT WATER
FLOW
TEMPERATURE
>40 ûC
REPLACE
CONTROL
BOARD
TURN DHW
THERMOSTAT AT
MAX.
B
IS
THERE A
VOLTAGE >4 Vdc
BETWEEN TERMINALS
M3.10 & M3.11
ON PCB
CHECK FAN, WIRING
AND CONNECTIONS,
DIFFERENTIAL ANALOG
PRESSURE SWITCH AND
CONTROL BOARD
IS
FAN
ON?
CHECK FLUE
VENTURI TUBE
IS
D.A.P.S.
OK?
REPLACE DIFFERENTIAL
ANALOG PRESSURE
SWITCH
VOKERA
LINEA PLUS AG
Rev. 1 08/03/2000
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
Page view 35
1 2 ... 31 32 33 34 35 36 37 38 39 40 41 ... 51 52