5.12 FINAL CHECKS
ENSURE ALL TEST NIPPLES ON THE AP-
PLIANCE GAS VALVE HAVE BEN TIGHT-
ENED AND CHECKED FOR SOUNDNESS.
ENSURE THE APPLIANCE FLUE SYSTEM
IS FITTED CORRECTLY AND IS PROPERLY
SECURED.
ENSURE ALL PIPE WORK IS RE-CHECKED
FOR SOUNDNESS.
RE-FIT APPLIANCE CASING.
COMPLETE APPLIANCE LOGBOOK.
Complete details of the boiler, controls, installa-
tion, and commissioning in the logbook supplied
with the boiler. This is an important document,
which must be correctly completed and handed
to the user. Failure to install and commission
the appliance to the manufacturers instructions
may invalidate the warranty.
5.13 INSTRUCTING THE USER
Hand over all documentation supplied with this
appliance – including these instructions – and ex-
plain the importance of keeping them in a safe
place.
Explain to the user how to isolate the appliance
from the gas, water, and electricity supplies, and
the locations of all drain points.
Show the user how to operate the appliance and
any associated controls correctly.
Show the user the location of the filling valve and
how to top-up the system pressure correctly, and
show the location of all manual air release points.
Explain to the user how to turn off the appliance
for both long and short periods and advise on the
necessary precautions to prevent frost damage.
Explain to the user that for continued safe and
efficient operation, the appliance must be serv-
iced annually by a competent person.
SECTION 6 SERVICING
6.1 GENERAL
To ensure the continued safe and efficient op-
eration of the appliance, it is recommended that
it is checked and serviced at regular intervals.
To ensure correct and safe operation of the ap-
pliance, it is essential that any worn or failed com-
ponent be replaced only with a genuine Vokera
spare part.
The frequency of servicing will depend upon the
particular installation conditions, but in general,
once per year should be adequate.
It is the law that any servicing work is carried out
by competent person such as a Vokera engineer,
an approved service agent, British Gas, or other
CORGI registered personnel.
The following instructions apply to the appliance
and its controls, but it should be remembered that
the central heating and the domestic hot water
systems would also require attention from time
to time.
6.2 ROUTINE ANNUAL SERVICING
Check the operation of the appliance and ensure
it functions as described in section 7. Compare
the performance of the appliance with its design
specification. The cause of any noticeable dete-
rioration should be identified and rectified with-
out delay.
Thoroughly inspect the appliance for signs of
damage or deterioration especially the flue sys-
tem and the electrical apparatus.
Check and adjust – if necessary – all burner pres-
sure settings. (See 7.3)
Check and adjust – if necessary – the system
design pressure. (See 5.10)
Carry out an analysis of the flue gases (see 7.4),
and visually check the condition of the entire flue
assembly. Compare the results with the appli-
ance design specification. Any deterioration in
performance must be identified and rectified with-
out delay.
Ensure both flue venturis are clean and free from
any debris or obstruction.
Ensure both the burner and heat exchanger are
clean and free from any debris or obstruction.
6.3 REPLACEMENT OF COMPONENTS
Although it is anticipated that this appliance will
give years of reliable, trouble free service, the
life span of components will be determined by
factors such as operating conditions and usage.
Should the appliance develop a fault, the fault
finding section will assist in determining which
component is malfunctioning.