VOKERA Linea Service Manual Page 40

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 39
38
Linea
REPLACE
CONTROL
BOARD
REMOVE
JUMPER
IS
TIMER JUMPER
ON JP9
WAIT 3 MIN.
RESTART
THE TEST
DO
BURNER AND FAN
SWITCH ON
IS
WATER FLOW
TEMPERATURE
>80 ûC
WAIT WATER
FLOW
TEMPERATURE
< 80 ûC
REPLACE
CONTROL
BOARD
REPLACE
CONTROL
BOARD
REMOVE
JUMPER
IS
TIMER JUMPER
ON
RESTART THE
TEST
C1
DO
BURNER AND FAN
SWITCH ON
REMOVE THE LINK
BETWEEN PIN M16.TA
AND M16.TA ON
CONTROL BOARD
WAIT 30 SEC.
END
DO
BURNER,
FAN AND PUMP
SWITCH
OFF
C
IS
THERE A
VOLTAGE < 1 Vdc
BETWEEN TERMINALS
M3.10 & M3.11
ON PCB
CHECK FAN, WIRING
AND CONNECTIONS,
DIFFERENTIAL ANALOG
PRESSURE SWITCH AND
CONTROL BOARD
IS
FAN
ON?
CHECK FLUE
VENTURI
IS
D.A.P.S.
OK?
REPLACE DIFFERENTIAL
ANALOG PRESSURE
SWITCH
IS
THERE A
VOLTAGE >4 Vdc
BETWEEN TERMINALS
M3.10 & M3.11
ON PCB
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
Page view 39
1 2 ... 35 36 37 38 39 40 41 42 43 44 45 ... 51 52

Comments to this Manuals

No comments