VOKERA Linea Service Manual Page 43

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 42
41
Linea
FUNCTIONAL DIAGRAM
NOTE: L-N-E CONNECTION IS ADVISABLE
CONTROL SWITCHING OF TIME CLOCK AND ROOM THERMOSTAT IS 230 V.a.c.
R.T. Room thermostat
TS H Heat time switch
S.F.S. Domestic hot water flow switch
P.S. Pressure switch
H.L. Hight limit thermostat
S.R. Heat thermistor
S.S. Domestic hot water thermistor
MOD Modulator
F Fan
P Pump
3W 3 way motor
SP\SE E. Spark\Sense electrode
OPE Gas valve solenoids
B.C.B. Burner control board
B.E.B. Boiler control board
S.B. Secondary board
JP6 Pre-heating jumper
JP8 Natural gas or L.P.G. selector
JP9 Timer on- off selector
JP7 Room thermostat or remote control jumper
PT2 Central heating temperature control
PT3 Domestic hot water temperature control
PT1 (S.B.) Selection of 0-reset / winter - summer
DS1÷DS2 Temperature / alarm display
TA1 Combustion test
F1 Fuse 100 mA F (on 24V circuit)
F2 Fuse 2 A F (on 230 V circuit)
RL1 Ignition relay
RL2 Pump relay
RL3 3 way relay
IS01 Fan triac
L1 Led OK (green)
L2 Led alarm (blink red)
TRF1 Transformer
PAD Differential analogue pressure switch
T.B. Burner thermostat
Page view 42