Page view 26
25
Linea
Fig. 33
6.20 DHW FLOW SWITCH fig. 33
Carry out component removal procedure as de-
scribed in 6.4.
Disconnect and remove the cold water inlet pipe
(1,2) from the DHW flow switch & DHW heat ex-
changer. Disconnect the wiring to the DHW flow
switch. Remove the locking pin (3) from the DHW
flow switch and lift the DHW flow switch housing
from its seating, taking care not to lose the float
contained within the housing. Replace in the re-
verse order ensuring that the housing is firmly
inserted onto its seating. Ensure all seals are in
good condition, taking care to ensure they are
replaced correctly.
6.21 DHW HEAT EXCHANGER
Carry out component removal procedure as de-
scribed in 6.4.
Locate and remove the screws (1) that secure
the heat exchanger to the DHW manifolds. Care-
fully remove the heat exchanger from its location
taking care not to spill any residual water. Re-
place in the reverse order ensuring that the heat
exchanger ‘O’ ring seals are correctly inserted
into the DHW manifolds. Ensure all seals are in
good condition, taking care to ensure they are
replaced correctly.
6.22 VALVE ACTUATOR fig. 35
Carry out component removal procedure as de-
scribed in 6.4.
Remove the locking pin (1) that secures the ac-
tuator to the heating manifold. Disconnect the
electrical plug (2) from the actuator. Replace in
the reverse order.
6.23 DIVERTOR VALVE ASSEMBLY Fig. 36
Carry out component removal procedure as de-
scribed in 6.4.
Remove the valve actuator as described in 6.22.
Locate and remove the 5-screws (2) that secure
the valve housing cover to the heating manifold.
Gently prise the valve seating assembly and cover
(3) from the manifold. Replace in the reverse or-
der ensuring that the seating assembly is inserted
properly. . Ensure all seals are in good condition,
taking care to ensure they are replaced correctly.
Fig. 34
Fig. 35
Fig. 36
6.24 SECONDARY THER-
MISTOR fig. 37
Carry out component
removal procedure as
described in 6.4. Pull
back the protective
cover from the thermis-
tor and disconnect the
electrical plug. Using a
13mm spanner slacken
and remove the ther-
mistor and sealing
washer from the DHW
heat exchanger mani-
fold. Replace in the re-
verse order.
Fig. 37